CMS5100 ICU Medical NIBP SpO2 Portable Patient Monitor

Category:

Description

ICU Medical NIBP SpO2 Portable Patient Monitor Use:

The CMS5100 ICU Medical NIBP SpO2 Portable Patient Monitor is a crucial tool for monitoring vital signs, including blood oxygen saturation (SpO2), pulse rate, and non-invasive blood pressure (NIBP). It is extensively used by healthcare professionals, including doctors, nurses, and medical technicians, to quickly and accurately assess a patient’s vital parameters. This device is particularly valuable in Intensive Care Units (ICUs), emergency rooms, operating rooms, and during patient transport within ambulances. Additionally, it serves as an excellent training tool for medical students and nurses, providing hands-on experience in patient monitoring. Its compact and portable design makes it suitable for use in various healthcare settings, including surgery centers, hospitals, clinics, and community healthcare.

Product Specifications:

The CMS5100 ICU Medical NIBP SpO2 Portable Patient Monitor offers a range of features designed to provide accurate and reliable readings with ease of use:

Features:

  • Compact and Portable: Designed for easy transportation and usage in both indoor and outdoor settings, including ambulances.
  • User-Friendly Interface: Features a simple and intuitive interface, making it easy for users to operate.
  • Built-in Rechargeable Battery: Ensures uninterrupted monitoring with its reliable lithium-polymer battery.
  • Comprehensive Monitoring: Suitable for adult, pediatric, and neonatal patients, providing all-round monitoring capabilities.
  • High-Resolution Display: 2.8” color TFT LCD with a resolution of 320×240, along with red and yellow highlight LEDs.
  • Visual and Audible Alarms: Alerts for systolic pressure (SYS), diastolic pressure (DIA), mean pressure (MAP), SpO2, and pulse rate (PR), with customizable upper and lower limits.
  • Data Storage: Unique flash memory capable of storing up to 2000 NIBP data entries and 78000 SpO2 data entries.
  • Trend Review: Allows review of NIBP trend graphs within 24 hours and SpO2 and pulse rate trend graphs within 20 hours.

Performance:

NIBP Monitoring:

  • Measurement Method: Oscillometry.
  • Measurement Mode: Manual/Auto/Continuous.
  • Auto Measurement Interval: Adjustable from 1 to 90 minutes.
  • Resolution: 1mmHg.
  • Accuracy: Maximum mean deviation ≤±5mmHg, maximum standard deviation ≤8mmHg.
  • Overpressure Protection: Double protection through software and hardware.

Measurement Range:

  • Adult:
    • Systolic Pressure: 40mmHg~270mmHg
    • Mean Pressure: 20mmHg~235mmHg
    • Diastolic Pressure: 10mmHg~215mmHg
  • Pediatric:
    • Systolic Pressure: 40mmHg~200mmHg
    • Mean Pressure: 20mmHg~165mmHg
    • Diastolic Pressure: 10mmHg~150mmHg
  • Neonatal:
    • Systolic Pressure: 40mmHg~135mmHg
    • Mean Pressure: 20mmHg~110mmHg
    • Diastolic Pressure: 10mmHg~100mmHg

SpO2 Monitoring:

  • Continuous Real-Time Measuring: Adopts digital SpO2 technology with strong anti-interference capability.
  • Display Parameters: SpO2, pulse rate, SpO2 Plethysmogram, bar graph, and trend graphs for SpO2 and pulse rate.

SpO2 Measuring Range:

  • 0%~100% (Resolution: 1%).
  • Accuracy: ±2% in the range of 70%-100%, unspecified below 70%.

Pulse Rate Measuring Range:

  • 30bpm~250bpm (Resolution: 1bpm).
  • Accuracy: ±2bpm or ±2%, whichever is greater.

Measurement Performance in Weak Filling Conditions:

  • Accurate readings with a pulse-filling ratio of 0.4%, SpO2 error ±4%, and pulse rate error ±2bpm or ±2%, whichever is greater.
  • Resistance to Surrounding Light: Deviation of less than ±1% between measurements taken in light and dark conditions.

Accessories:

Standard:

  • A power cord.
  • A power adapter.
  • A SpO2 probe.
  • An adult NIBP cuff.
  • An extending tube for blood pressure.

Physical Characteristics:

  • Dimensions: 190(L)×162(W)×240(H) mm.
  • Weight: 1.6kg.
  • Packaging Dimensions: 402(L)×228(W)×320(H) mm.